| BS 2574-1:1991 | Lower limb orthoses. Guide to the design and manufacture of lower limb orthoses, excluding foot orthoses |
| BS 2574-2:1994 | Lower limb orthoses. Specification for hip, knee and ankle joints for lower limb orthoses |
| BS 2574-3:1990 | Lower limb orthoses. Method for the determination of mechanical properties of metal knee joint and side member assemblies |
| BS 2931:1957 | Specification for steel ankle joints for steel orthopaedic appliances |
| BS 3531-11:1991* ISO 8827:1988 | Implants for osteosynthesis. Implants for osteosynthesis. Specification for staples with parallel legs |
| BS 3531-14.1:1990 | Implants for osteosynthesis. Intramedullary nailing systems. Specification for the dimensions of nails of clover leaf and V-shaped cross section and dimensions of extraction hooks |
| BS 3531-14.2:1990 | Implants for osteosynthesis. Intramedullary nailing systems. Specification for medullary pins (Rush type) and introducer/extractors |
| BS 3531-15:1992* ISO 8615:1991 | Implants for osteosynthesis. Specification for devices for the fixation of the ends of the femur in adults |
| BS 3531-23.1:1991* ISO 9585:1990 | Implants for osteosynthesis. Bone plates. Method for determination of bending strength and stiffness |
| BS 3531-23.2:1993* ISO 9269:1988 | Implants for osteosynthesis. Bone plates. Specification for holes and slots for use with screws of 4,5 mm, 4,2 mm, 4,0 mm, 3,9 mm, 3,5 mm and 2,9 mm nominal sizes |
| BS 3531-23.3:1991* ISO 5836:1988 | Implants for osteosynthesis. Bone plates. Specification for holes corresponding to screws with asymmetrical thread and spherical undersurfaces |
| BS 3531-5.1:1997* ISO 8319-1:1996 | Implants for osteosynthesis. Bone screws and auxiliary equipment. Specification for keys for use with screws having heads with hexagon socket |
| BS 3531-5.2:1990* ISO 8319-2:1986 | Implants for osteosynthesis. Bone screws and auxiliary equipment. Specification for screwdrivers for screws having heads with single slot, cruciate slot or cross-recess |
| BS 3531-5.3:1991* ISO 5835:1991 | Implants for osteosynthesis. Bone screws and auxiliary equipment. Specification for the dimensions of screws having hexagonal drive connection, spherical under-surfaces and asymmetrical thread |
| BS 3531-5.4:1993* ISO 9268:1988 | Implants for osteosynthesis. Bone screws and auxiliary equipment. Specification for screws having symmetrical and asymmetrical thread and conical undersurfaces |
| BS 3531-5.5:1990 | Implants for osteosynthesis. Bone screws and auxiliary equipment. Specification for taps and drills |
| BS 3531-5.6:1991* ISO 6475:1989 | Implants for osteosynthesis. Bone screws and auxiliary equipment. Specification for the mechanical requirements and test methods for screws having asymmetrical thread and spherical undersurface |
| BS 3531-5.7:1991* ISO 9714-1:1991 | Implants for osteosynthesis. Bone screws and auxiliary equipment. Specification for drill bits, taps and countersink cutters |
| BS 3531-6.1:1990 | Implants for osteosynthesis. Skeletal pins and wires. Specification for general requirements |
| BS 3531-6.2:1991* ISO 5838-2:1991 | Implants for osteosynthesis. Skeletal pins and wires. Specification for dimensions of Steinmann skeletal pins |
| BS 3531-6.3:1994* ISO 5838-3:1993 | Implants for osteosynthesis. Skeletal pins and wires. Specification for Kirschner skeletal wires |
| BS 3531:Part 5:Section 5.1:1990* ISO 8319/1-1986 | Implants for osteosynthesis. Bone screws and auxiliary equipment. Specification for keys for use with screws having heads with hexagon socket |
| BS 4106:1967 | Specification for surgical stainless steel monofilament wire. Fully softened |
| BS 6324-1:1983 | Terms relating to surgical implants. Glossary of general medical terms |
| BS 6324-2:1983 | Terms relating to surgical implants. Glossary of terms relating to mechanics |
| BS 6324-3:1983 | Terms relating to surgical implants. Glossary of terms relating to materials |
| BS 6324-4:1983 | Terms relating to surgical implants. Glossary of orthopaedic surgical terms |
| BS 6324-5:1990* ISO TR 9586:1988 | Terms relating to surgical implants. Guidance on the usage of the terms 'valgus' and 'varus' in orthopaedic surgery |
| BS 6444-1:1990* ISO 5840:1989 | Cardiovascular implants. Methods of test for heart valve substitutes and requirements for their packaging and labelling |
| BS 6788-2:1990 | Neurosurgical implants. Specification for marking and packaging of implantable neural stimulators |
| BS 6788-3:1990 | Neurosurgical implants. Specification for self-closing intracranial aneurysm clips |
| BS 6788:Part 1:1986 | Neurosurgical implants. Specification for sterile, single-use hydrocephalus shunts and components |
| BS 6902-1:1990* EN 50061:1988 | Cardiac pacemakers. Specification for implantable cardiac pacemakers |
| BS 6902-1:Supplement No. 1:1996* EN 50061/A1:1995 | Cardiac pacemakers. Specification for implantable cardiac pacemakers. Electromagnetic compatibility |
| BS 6902-2:1987* ISO 5841/2-1986 | Cardiac pacemakers. Method for reporting the clinical performance of populations of pulse generators |
| BS 7251-10:1992* ISO 7206-6:1992 | Orthopaedic joint prostheses. Method of determination of endurance properties of the head and neck region of stemmed femoral components of hip joint prostheses |
| BS 7251-12:1995* ISO 7206-8:1995 | Orthopaedic joint prostheses. Specification for endurance of stemmed femoral components with application of torsion |
| BS 7251-13:1995* ISO 7206-9:1994 | Orthopaedic joint prostheses. Method for determination of resistance to torque of head fixation of stemmed femoral components |
| BS 7251-14:1998* ISO 7207-2:1998 | Orthopaedic joint prostheses. Components for partial and total knee-joint prostheses. Articulating surfaces made of metal, ceramic and plastics materials |
| BS 7251-1:1990 | Orthopaedic joint prostheses. Specification for general requirements |
| BS 7251-2:1995* ISO 7207-1:1994 | Orthopaedic joint prostheses. Specification for classification, definitions and designation of dimensions of femoral and tibial components for partial and total knee joint prostheses |
| BS 7251-3:1997* ISO 7206-1:1995 | Orthopaedic joint prostheses. Specification for classification and designation of dimensions for hip joint prostheses |
| BS 7251-4:1997* ISO 7206-2:1996 | Orthopaedic joint prostheses. Specification for articulating surfaces made of metallic, ceramic and plastics materials of hip joint prostheses |
| BS 7251-5:1990 | Orthopaedic joint prostheses. Method for determination of endurance properties of stemmed femoral components of hip joint prostheses with application of torsion |
| BS 7251-7:1990* ISO TR 9325:1989 | Orthopaedic joint prostheses. Guide to hip joint simulators |
| BS 7251-8:1990* ISO/TR 9326:1989 | Orthopaedic joint prostheses. Guide to laboratory evaluation of change of form of bearing surfaces of hip joint prostheses |
| BS 7251:Part 11:1993* ISO 7206-7:1993 | Orthopaedic joint prostheses. Specification for endurance of stemmed femoral components without application of torsion |
| BS 7251:Part 2:1990* ISO 7207/1-1985 | Orthopaedic joint prostheses. Specification for classification and designation of dimensions for knee joint prostheses |
| BS 7251:Part 3:1990 | Orthopaedic joint prostheses. Specification for classification, designation of dimensions and requirements for hip joint prostheses |
| BS 7251:Part 4:1990* ISO 7206-2:1987 | Orthopaedic joint prostheses. Specification for bearing surfaces of hip joint prostheses |
| BS 7251:Part 6:1990* ISO 7206-3:1988 | Orthopaedic joint prostheses. Method for determination of endurance properties of stemmed femoral components of hip joint prostheses without application of torsion |
| BS 7251:Part 9:1992* ISO 7206-5:1992 | Orthopaedic joint prostheses. Method of determination of resistance to static load of the head and neck region of stemmed femoral components of hip joint prostheses |
| BS 7252-10:1997* ISO 5832-10:1996 | Metallic materials for surgical implants. Specification for wrought titanium 5-aluminium 2,5-iron alloy |
| BS 7252-11:1995* ISO 5832-11:1994 | Metallic materials for surgical implants. Specification for wrought titanium 6-aluminium 7-niobium alloy |
| BS 7252-12:1997* ISO 5832-12:1996 | Metallic materials for surgical implants. Specification for wrought cobalt-chromium-molybdenum alloy |
| BS 7252-13:1997* ISO 13782:1996 | Metallic materials for surgical implants. Specification for unalloyed tantalum for surgical implant applications |
| BS 7252-1:1997* ISO 5832-1:1997 | Metallic materials for surgical implants. Specification for wrought stainless steel |
| BS 7252-2:1994* ISO 5832-2:1993 | Metallic materials for surgical implants. Specification for unalloyed titanium |
| BS 7252-3:1997* ISO 5832-3:1996 | Metallic materials for surgical implants. Specification for wrought titanium 6-aluminium 4-vanadium alloy |
| BS 7252-4:1997* ISO 5832-4:1996 | Metallic materials for surgical implants. Specification for cobalt-chromium-molybdenum casting alloy |
| BS 7252-5:1994* ISO 5832-5:1993 | Metallic materials for surgical implants. Specification for wrought cobalt-chromium-tungsten-nickel alloy |
| BS 7252-6:1997* ISO 5832-6:1997 | Metallic materials for surgical implants. Specification for wrought cobalt-nickel-chromium-molybdenum alloy |
| BS 7252-7:1994* ISO 5832-7:1994 | Metallic materials for surgical implants. Specification for cobalt-chromium-nickel-molybdenum-iron alloy |
| BS 7252-8:1997* ISO 5832-8:1997 | Metallic materials for surgical implants. Specification for wrought cobalt-nickel-chromium-molybdenum-tungsten-iron alloy |
| BS 7252-9:1993* ISO 5832-9:1992 | Metallic materials for surgical implants. Specification for high-nitrogen stainless steel |
| BS 7252:Part 10:1994* ISO 5832-10:1993 | Metallic materials for surgical implants. Specification for wrought titanium 5-aluminium 2.5-iron alloy |
| BS 7252:Part 1:1990* ISO 5832-1:1987 | Metallic materials for surgical implants. Specification for wrought stainless steel |
| BS 7252:Part 3:1990 | Metallic materials for surgical implants. Specification for wrought titanium 6-aluminium 4-vanadium alloy |
| BS 7252:Part 4:1990* ISO 5832/IV:1978 | Metallic materials for surgical implants. Specification for cobalt-chromium-molybdenum casting alloy |
| BS 7252:Part 6:1990* ISO 5832/6-1980 | Metallic materials for surgical implants. Specification for wrought cobalt-nickel-chromium-molybdenum alloy |
| BS 7252:Part 8:1990* ISO 5832/8:1984 | Metallic materials for surgical implants. Specification for wrought cobalt-nickel-chromium-molybdenum-tungsten-iron alloy |
| BS 7253-1:1993* ISO 5833:1992 | Non-metallic materials for surgical implants. Specification for acrylic resin cement |
| BS 7253-2:1997* ISO 6474:1994 | Non-metallic materials for surgical implants. Specification for ceramic materials based on high purity alumina |
| BS 7253-3:1990 | Non-metallic materials for surgical implants. Specification for surgical implants made of heat-vulcanized silicone elastomer |
| BS 7253-6:1997* ISO 13356:1997 | Non-metallic materials for surgical implants. Specification for ceramic materials based on yttria-stabilized tetragonal zirconia (Y-TZP) |
| BS 7253:Part 2:1990* ISO 6474-1981 | Non-metallic materials for surgical implants. Specification for ceramic materials based on alumina |
| BS 7253:Part 4:1990 | Non-metallic materials for surgical implants. Specification for ultra-high molecular mass polyethylene in powder form |
| BS 7253:Part 5:1990 | Non-metallic materials for surgical implants. Specification for ultra-high molecular mass polyethylene in moulded form |
| BS 7254-2:1990 | Orthopaedic implants. Specification for general requirements for materials and finish |
| BS 7254-3:1990 | Orthopaedic implants. Recommendations for care and handling |
| BS 7254-4:1990 | Orthopaedic implants. Recommendations for retrieval and examination of implants and associated tissues |
| BS 7254-5:1990 | Orthopaedic implants. Specification for production of castings made of cobalt-chromium-molybdenum alloy |
| BS 7254-6.2:1990 | Orthopaedic implants. Forgings. Method for specifying forgings |
| BS 7254:Part 1:1990* ISO 6018:1987 | Orthopaedic implants. Specification for marking, packaging and labelling |
| BS 7254:Part 6:Section 6.1:1990 | Orthopaedic implants. Forgings. Specification for production of forgings |
| BS 7297:Part 1:1990* ISO 8637:1989 | Haemodialysers and related equipment. Specification for haemodialysers, haemofilters and haemoconcentrators |
| BS 7297:Part 2:1990* ISO 8638:1989 | Haemodialysers and related equipment. Specification for extracorporeal circuits for use with haemodialysers, haemofilters and haemoconcentrators |
| BS 7313-1.1:1990* ISO 8549-1:1989 | Prosthetics and orthotics. Terminology. Glossary of general terms relating to external limb prostheses and external orthoses |
| BS 7313-1.2:1990* ISO 8549-2:1989 | Prosthetics and orthotics. Glossary of terms relating to external limb prostheses and wearers of external limb prostheses |
| BS 7313-1.3:1990* ISO 8549-3:1989 | Prosthetics and orthotics. Terminology. Glossary of terms relating to external orthoses |
| BS 7313-2:1990* ISO 8548-1:1989 | Prosthetics and orthotics. Method of describing limb deficiencies present at birth |
| BS 7313-3:1993* ISO 8548-2:1993 | Prosthetics and orthotics. Method of describing lower limb amputation stumps |
| BS 7313-4:1993* ISO 8548-3:1993 | Prosthetics and orthotics. Method of describing upper limb amputation stumps |
| BS 7730:1994* ISO 9583:1993 | Method for liquid penetrant inspection of metallic surgical implants |
| BS 7731:1994* ISO 9584:1993 | Method for radiographic examination of cast metallic surgical implants |
| BS 7778:1994* ISO 11318:1993 | Specification for connector assembly DF-1 for implantable cardiac defibrillators |
| BS 8432:2005 | Spinal orthoses. Guide to design |
| BS EN 12006-1:1999 | Non-active surgical implants. Particular requirements for cardiac and vascular implants. Heart valve substitutes |
| BS EN 12006-2:1998 | Non-active surgical implants. Particular requirements for cardiac and vascular implants. Vascular prostheses including cardiac valve conduits |
| BS EN 12006-3:1999 | Non-active surgical implants. Particular requirements for cardiac and vascular implants. Endovascular devices |
| BS EN 12010:1998 | Non-active surgical implants. Joint replacement implants. Particular requirements |
| BS EN 12180:2000 | Non-active surgical implants. Body contouring implants. Specific requirements for mammary implants |
| BS EN 12523:1999 | External limb prostheses and external orthoses. Requirements and test methods |
| BS EN 12563:1999 | Non-active surgical implants. Joint replacement implants. Specific requirements for hip joint replacement implants |
| BS EN 12564:1999 | Non-active surgical implants. Joint replacement implants. Specific requirements for knee joint replacement implants |
| BS EN 14299:2004 | Non-active surgical implants. Particular requirements for cardiac and vascular implants. Specific requirements for arterial stents |
| BS EN 45502-1:1998 | Active implantable medical devices. General requirements for safety, marking and information to be provided by the manufacturer |
| BS EN 45502-2-1:2003 | Active implantable medical devices. Particular requirements for active implantable medical devices intended to treat bradyarrhythmia (cardiac pacemakers) |
| BS EN 50077:1993 | Specification for low profile connectors (IS-1) for implantable pacemakers |
| BS EN 60601-2-31:1995* BS 5724-2.31:1995 | Medical electrical equipment. Particular requirements for safety. Specification for external cardiac pacemakers with internal power source |
| BS EN ISO 10328:2006 | Prosthetics. Structural testing of lower-limb prostheses. Requirements and test methods |
| BS EN ISO 14602:1998 | Non-active surgical implants. Implants for osteosynthesis. Particular requirements |
| BS EN ISO 14630:1998 | General requirements for non-active surgical implants |
| BS EN ISO 14630:2005 | Non-active surgical implants. General requirements |
| BS EN ISO 16054:2002 | Implants for surgery. Minimum data sets for surgical implants |
| BS EN ISO 22523:2006 | External limb prostheses and external orthoses. Requirements and test methods |
| BS EN ISO 22675:2006 | Prosthetics. Testing of ankle-foot devices and foot units. Requirements and test methods |
| BS EN ISO 5840:2005 | Cardiovascular implants. Cardiac valve prostheses |
| BS EN ISO 9713:2004 | Neurosurgical implants. Self-closing intracranial aneurysm clips |
| BS ISO 10328-1:1996 | Prosthetics.Structural testing of lower-limb prostheses. Test configurations |
| BS ISO 10328-2:1996 | Prosthetics.Structural testing of lower-limb prostheses. Test samples |
| BS ISO 10328-3:1996 | Prosthetics.Structural testing of lower-limb prostheses. Principal structural tests |
| BS ISO 10328-4:1996 | Prosthetics.Structural testing of lower-limb prostheses. Loading parameters of principal structural tests |
| BS ISO 10328-5:1996 | Prosthetics.Structural testing of lower-limb prostheses. Supplementary structural tests |
| BS ISO 10328-6:1996 | Prosthetics.Structural testing of lower-limb prostheses. Loading parameters of supplementary structural tests |
| BS ISO 10328-7:1996 | Prosthetics.Structural testing of lower-limb prostheses. Test submission document |
| BS ISO 10328-8:1996 | Prosthetics.Structural testing of lower-limb prostheses. Test report |
| BS ISO 11318:2002 | Cardiac defibrillators. Connector assembly DF-1 for implantable defibrillators. Dimensions and test requirements |
| BS ISO 13404:2007 | Prosthetics and orthotics. Categorization and description of external orthoses and orthotic components |
| BS ISO 13405-1:1996 | Prosthetics and orthotics. Classification and description of prosthetic components. Classification of prosthetic components |
| BS ISO 13405-2:1996 | Prosthetics and orthotics. Classification and description of prosthetic components. Description of lower-limb prosthetic components |
| BS ISO 13405-3:1996 | Prosthetics and orthotics. Classification and description of prosthetic components. Description of upper-limb prosthetic components |
| BS ISO 13779-1:2000 | Impants for surgery. Hydroxyapatite. Ceramic hydroxyapatite |
| BS ISO 13779-2:2000 | Impants for surgery. Hydroxyapatite. Coatings of hydroxyapatite |
| BS ISO 13779-4:2002 | Implants for surgery. Hydroxyapatite. Determination of coating adhesion strength |
| BS ISO 14242-1:2002 | Implants for surgery. Wear of total hip joint prostheses. Loading and displacement parameters for wear-testing machines and corresponding environmental conditions for test |
| BS ISO 14242-2:2000 | Implants for surgery. Wear of total hip joint prostheses. Methods of measurement |
| BS ISO 14243-1:2002 | Implants for surgery. Wear of total knee joint prostheses. Loading and displacement parameters for wear-testing machines with load control and corresponding environmental conditions for test |
| BS ISO 14243-2:2000 | Implants for surgery. Wear of total knee joint prostheses. Methods of measurement |
| BS ISO 14243-3:2004 | Implants for surgery. Wear of total knee-joint prostheses. Loading and displacement parameters for wear-testing machines with displacement control and corresponding environmental conditions for test |
| BS ISO 14879-1:2000 | Implants for surgery. Total knee-joint prostheses. Determination of endurance properties of knee tibial trays |
| BS ISO 14949:2001 | Implants for surgery. Two-part addition-cure silicone elastomers |
| BS ISO 15032:2000 | Prostheses. Structural testing of hip joints |
| BS ISO 15142-1:2003 | Implants for surgery. Metal intramedullary nailing systems. Intramedullary nails |
| BS ISO 15142-2:2003 | Implants for surgery. Metal intramedullary nailing systems. Locking components |
| BS ISO 15142-3:2003 | Implants for surgery. Metal intramedullary nailing systems. Connection devices and reamer diameter measurements |
| BS ISO 15374:1998 | Implants for surgery. Requirements for production of forgings |
| BS ISO 15674:2001 | Cardiovascular implants and artificial organs. Hard-shell cardiotomy/venous reservoir systems (with/without filter) and soft venous reservoir bags |
| BS ISO 15675:2001 | Cardiovascular implants and artificial organs. Cardiopulmonary bypass systems. Arterial line blood filters |
| BS ISO 16428:2005 | Implants for surgery. Test solutions and environmental conditions for static and dynamic corrosion tests on implantable materials and medical devices |
| BS ISO 17853:2003 | Wear of implant materials. Polymer and metal wear particles. Isolation, characterization and quantification |
| BS ISO 25539-1:2003 | Cardiovascular implants. Endovascular devices. Endovascular prostheses |
| BS ISO 5832-2:1999 | Implants for surgery. Metallic materials. Unalloyed titanium |
| BS ISO 5833:2002 | Implants for surgery. Acrylic resin cements |
| BS ISO 5834-1:1998 | Implants for surgery. Ultra-high molecular weight polyethylene. Powder form |
| BS ISO 5834-1:2005 | Implants for surgery. Ultra-high-molecular-weight polyethylene. Powder form |
| BS ISO 5834-2:1998 | Implants for surgery. Ultra-high molecular weight polyethylene. Moulded forms |
| BS ISO 5834-4:2005 | Implants for surgery. Ultra-high molecular weight polyethylene. Oxidation index measurement method |
| BS ISO 5834-5:2005 | Implants for surgery. Ultra-high molecular weight polyethylene. Morphology assessment method |
| BS ISO 5841-2:2000 | Implants for surgery. Cardiac pacemakers. Reporting of clinical performance of populations of pulse generators or leads |
| BS ISO 7197:1997 | Neurosurgical implants. Sterile, single-use hydrocephalus shunts and components |
| BS ISO 7198:1998 | Cardiovascular implants. Tubular vascular prostheses |
| BS ISO 7206-10:2003 | Implants for surgery. Partial and total hip-joint prostheses. Determination of resistance to static load of modular femoral heads |
| BS ISO 7206-4:2002 | Implants for surgery. Partial and total hip joint prostheses. Determination of endurance properties of stemmed femoral components |
| BS ISO 8548-4:1998 | Prosthetics and orthotics. Limb deficiencies. Description of causal conditions leading to amputation |
| BS ISO 8548-5:2003 | Prosthetics and orthotics. Limb deficiencies. Description of the clinical condition of the person who has had an amputation |
| BS ISO 8551:2003 | Prosthetics and orthotics. Functional deficiencies. Description of the person to be treated with an orthosis, clinical objectives of treatment, and functional requirements of the orthosis |